Search results for "Harmonic distortion"

showing 10 items of 67 documents

Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems

2008

This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…

Total harmonic distortionEngineeringbusiness.industrySystem testingAC powerDetection of harmonic sources harmonic distortion power quality power system harmonics reactive powerPower (physics)Electric power systemPower system simulationHarmonicElectronic engineeringMetering modeElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationIEEE Transactions on Instrumentation and Measurement
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics

2011

This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…

PhysicsTotal harmonic distortionFrequency responsebusiness.industryAcousticsElectrical engineeringFundamental frequencycurrent transducerRogowski coilCurrent measurement current transducer frequency response harmonic distortion power system harmonics Rogowski coil.harmonic distortionHarmonic analysisAmplitudeHarmonicsHarmonicpower system harmonicElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coil
researchProduct

A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization

2012

This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …

EngineeringVirtual instrumentExperimental evaluationMeasurement uncertaintyNon-inductive currentsInput signalHarmonic distortionElectric power measurementlaw.inventionPC-basedData acquisitionlawExperimental testElectronic engineeringData acquisition harmonic distortion personal computer (PC) -based instrument power measurement power system measurements wattmetersElectrical and Electronic EngineeringSignal samplingInstrumentationVoltage dividersTotal harmonic distortionLow-cost solutionVirtual instrumentationbusiness.industryAnalog to digital convertersData acquisition boardExperimental characterizationVoltage dividerElectrical engineeringData acquisitionMetrological performanceWattmeterAccurate measurementCommercial softwareElectric powerPersonal computersPower qualityPersonal computerPower system measurementMeasurement uncertaintyUncertainty analysisbusinessHigh-accuracySettore ING-INF/07 - Misure Elettriche E ElettronicheWattmetersVoltage
researchProduct

A low cost and easy re-configurable instrument for power quality survey

2004

In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.

Measure (data warehouse)Total harmonic distortionEngineeringUser Friendlybusiness.industryElectromagnetic compatibilityDiscrete Fourier transformsReliability engineeringspectral leakageHarmonicsCalibrationElectronic engineeringPower qualityFrequency estimationbusinessVoltageProceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510)
researchProduct

An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters

2008

This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.

EngineeringTotal harmonic distortionbusiness.industryAcousticsAstrophysics::Instrumentation and Methods for AstrophysicsAC powerMetrologyElectric power systemHarmonicsHarmonicElectronic engineeringMetreenergy measurements harmonic distortion power quality power systemsbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Comparative evaluation of pulse width modulation techniques on effective DC link voltage utilization of grid connected inverter

2016

In this paper, comparison between two different Pulse Width Modulation (PWM) techniques employed for three phase voltage source inverter (VSI) is discussed. The three phase voltage source inverter is basic topology used to supply a grid. In this paper we have design a LC filter between the inverter and the grid in order to stabilize the output voltage. The filter gives sinusoidal three phase voltage at the output of the inverter with almost zero/less harmonic distortion. A suitable PWM technique is employed to obtain the required output voltage in the line side of the inverter. The PWM generation techniques used mainly based on sinusoidal based Pulse Width Modulation (SPWM) and Space Vector…

EngineeringPulse-frequency modulationTotal harmonic distortionThree-phasebusiness.industryElectronic engineeringInverterbusinessFrequency modulationVoltage referencePulse-width modulationVoltage2016 International Conference on Electrical, Electronics, and Optimization Techniques (ICEEOT)
researchProduct

Mathematical formulation of pulse amplitude modulation selective harmonic elimination in multilevel three phase inverters

2022

In this paper multilevel cascaded H-bridges (CHB) three phase inverters with 2n dc sources, n=1,2,3,... are considered and a mathematical formulation providing both 2n switching angles and dc voltage source to eliminate n+1 harmonics and their respective multiple from their output voltage waveform, is proposed. The computed angles don't depend on modulation index and the source voltages linearly vary with it. The proposed procedure finds the solution through an analytical formula that avoids to solve transcendental systems and presents very low computational cost. A lot of low order harmonics are eliminated, returning a very low total harmonic distortion (THD). Particularly for 9-level conf…

Total Harmonic Distortion (THD)Selective Harmonics Elimination (SHE)Selective Harmonics Mitigation (SHM)Settore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciCascaded H-bridges (CHB) Multilevel Inverters
researchProduct

Comparison of two different approaches for harmonic distortion sources assessment

2021

The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.

Total harmonic distortionHarmonic pollutionComputer scienceElectronic engineeringHarmonicPower qualityPoint of common couplingSingle pointGridEquivalent impedance transformsHarmonic Emission IEEE Std. 1459-2010 Power QualitySettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct